O-Ring Groove Calculator: Squeeze, Gland Fill and Stretch
Enter the O-ring cross-section and the groove dimensions with their tolerances. The calculator gives worst-case squeeze and gland fill and compares them with the guidance in the Parker O-Ring Handbook (sections 3.5 to 3.7).
Gland Check
All dimensions in the same unit. The defaults are the 2-104 to 2-116 row of Parker’s industrial reciprocating gland chart (Design Chart 5-2-a), with the groove width the chart lists for no Parbak (back-up) ring.
| Quantity | Minimum | Maximum |
|---|---|---|
| Squeeze | 0.0100 | 0.0180 |
| Squeeze, percent | 10.0% | 17.0% |
| Gland fill | 60.2% | 71.6% |
| Void | 28.4% | 39.8% |
- Maximum squeeze is above the 16 % Parker gives for dynamic seals. Parker allows up to 25 % for smaller cross-sections only (3.6); confirm with your seal supplier.
The Limits This Tool Compares Against
All from the Parker O-Ring Handbook, section III. The tool states a result against these figures and does not add any of its own.
| Item | Parker guidance | Section |
|---|---|---|
| Squeeze, dynamic | Maximum about 16 %; smaller cross-sections may be squeezed as much as 25 % | 3.6 |
| Squeeze, static | Maximum 30 % for most elastomers | 3.6 |
| Squeeze, minimum | About 0.2 mm (0.007 in) for all seals regardless of cross-section | 3.6 |
| Gland fill | 60 % to 85 %, optimum 75 % (25 % void); at least 10 % void | 3.7 |
| Stretch | Above 5 % assembled stretch not recommended; beyond 2 to 3 % the gland depth must be reduced to keep the squeeze | 3.5 |
How This Calculator Was Checked
The calculation is a plain function that is tested automatically against the source before any change is released.
| Check | Source | Result |
|---|---|---|
| Five size rows of the industrial reciprocating gland chart: minimum and maximum squeeze from W, tolerance and gland depth | Parker ORD 5700, Design Chart 5-2-a | All 10 absolute values match the printed 3 decimals |
| Same rows, squeeze in percent | Parker ORD 5700, Design Chart 5-2-a | Within 1 point of the printed integers (see note) |
| Stretch flattening formulas, observed and calculated curves | Parker ORD 5700, 3.5, Figure 3-3 | Formulas as printed; read-off at 8 % stretch agrees with the figure |
| Gland fill, squeeze with stretch correction, radial depth | Hand calculation | Match to 1e-6 or better |
| Inch and mm inputs of the same gland | Arithmetic | Identical percentages |
| Values exactly on a Parker limit (0.007 in, 16 %, 30 %, 85 %) are not flagged; values beyond are | Parker ORD 5700, 3.5 to 3.7 | Pass |
| Invalid input (depth range reversed, tolerance larger than W, one groove width only, stretch above 25 %) | — | Refused with a message |
Note on percentages: the chart prints integers and is not consistent about which W it divides by. For the 2-201 to 2-222 row the maximum is printed as 16 %, while 0.022 ÷ 0.143 gives 15.4 %; the tool shows 15.4 %. The 2007 edition of the handbook was read; the guidance figures should be rechecked against the current edition. Tool version 1.0 · last verified 2026-11-05.
Assumptions & Limitations
- The groove is treated as a rectangle with no corner radii, and the O-ring section as a circle of diameter W. Gland fill is computed with the free-state section; when the ring is stretched its section is smaller, so the fill shown is conservative.
- Percent squeeze with stretch correction is taken on the reduced section diameter, as Parker describes in 3.5. Stretch is entered as one value; its tolerance is not propagated.
- Parker’s Figure 3-3 is described as valid for approximation. For low stretch (0 to 5 %) Parker notes more recent research following a more complex function, which is not implemented. The two printed formulas also differ by about 0.19 points at 3 % stretch; they are used as printed.
- Parker gives “smaller cross-sections may be squeezed as much as 25 %” for dynamic seals without defining “smaller”. The tool flags 16 % to 25 % as conditional rather than as a pass or a fail.
- Not checked: extrusion gap and back-up rings, compound hardness and compression force, temperature, fluid compatibility and swell, surface finish, vacuum or gas sealing, rotary seals.
- The stretch input is written for a piston-type (male) gland, the case Parker discusses in 3.5. It does not cover rod (female) glands; leave it blank for those.
Common Questions
How is O-ring squeeze calculated?
- Squeeze is the cross-section W minus the gland depth L, usually quoted as a percentage of W. Because both W and L have tolerances, the worst cases are minimum W with maximum L (least squeeze) and maximum W with minimum L (most squeeze).
What is gland fill and why does it matter?
- Gland fill is the share of the groove cross-section taken up by the O-ring. Parker calls for 60 % to 85 % with 75 % optimum, and at least 10 % void, to allow for tolerance stack-up, swell and thermal expansion.
Why does stretching an O-ring change the squeeze?
- A stretched ring becomes thinner. Parker gives formulas for how much the section diameter shrinks with the percent stretch of the inside diameter, and says to apply the required squeeze to the reduced diameter.
Does it pick the O-ring size or groove width?
- No. It checks dimensions you have already chosen. Standard sizes and groove widths are listed in the Parker handbook and in your seal supplier’s catalogue.
Sources
- Parker Hannifin Corporation, O-Ring Division, “Parker O-Ring Handbook”, ORD 5700 (2007 edition): 3.5 Stretch (Figure 3-3), 3.6 Squeeze, 3.7 Gland Fill, and Design Chart 5-2-a, Industrial Reciprocating O-Ring Packing Glands. Handbook (PDF, third-party copy).
Parker is named only to cite its published handbook. SYZ Rod Ends is not affiliated with Parker Hannifin and the handbook’s tables are not reproduced here beyond the figures quoted above.